IN-NJ-K 50 100 200 300 500 800 Static Torque Sensor for Static torque measure

Group Force sensor
Min. Order 10 piece
Terms of Payment L/C, T/T
Update Time 2017-07-14
Item specifics
CatagoriesTorque Sensor
PriceUSD1-USD100
OriginalChina
Delivery time7-15 work days
Capacity50, 100, 200, 300, 500, 800
Protection classIP66
MaterialAlloy steel
ApplicationStatic torque measure
  • Description
  • Product review

Static torque measure alloy steel load cell


load cell




ItemsUNITTECHNICAL DATA
Rated capacities(Emax)N.m50, 100, 200, 300, 500, 800
SensitivitymV/V1~2
Total errorF.S±0.5, ±1%
Creep error(30min)F.S±0.05%
Zero balanceF.S±1%
TCOF.S/℃±0.05% / 10
TC SPANF.S/℃±0.05% / 10
Input impedanceΩ400±50
Output impedanceΩ352±3
Insulation impedance≥5000
Temperature range, operating-30~ +70
Maximum safe overloadF.S120%
Ultimate overloadF.S150%
Excitation, recommendV10-12V DC
Excitation, maximumV15V DC
Protection class IP66
Construction Alloy Steel
CablemLength: 5
mmDiameter: φ5
Wiring Exc+(Red) Exc-(Black) Sig+(Green) Sig-(White)


Share Beam Load Cell

  • NCI Mark V Load Cell
  • Sensortronics 60048SS Load Cell
  • Weigh-Tronix Mark V Load Cell

Share Beam Load Cell


Share Beam Load Cell

Capacities

25LB, 50LB, 100LB, 200LB, 400LB, 500LB, 1K LB

Rated Output

2.0 mV/V

Safe Overload

150%FS

Excitation Voltage

10-20V AC/DC

Input Resistance

385 ± 10 OHMS

Output Resistance

350 ± 3 OHMS

Zero Balance

±1.00%FS

Seal Type

Environmentally sealed, potted IP67

Non-linearity

±0.03%FS

Hysteresis

±0.02%FS

Repeatablity

±0.02%FS

Creep

±0.03%FS

Compensated Temperature Range:

-10 - +40

Temperature Effect on Zero

±0.02%FS/

Temperature Effect on Output

±0.001%FS/

Insulation Resistance

>5000 MEGOHMS

Load Cell Cable

4 Conductor, 10 FT

Load Cell Wiring

Green +EXC

Black –EXC

White +SIG

RED  -SIG

Braid/Yellow: Shield

 