IPW15B 7.5kg to 200kg Single Point Load Cell for platform scale

Group Single Point Load Cell
Min. Order 1 piece
Terms of Payment L/C
Update Time 2018-03-22
Item specifics
TypeSingle Point Load Cell
Materialaluminum load cell
Capacity7.5kg to 200kg
Sensitivity2.0
AccuracyC3MR
Input impedance300 ... 500
Output impedance330 ... 430 (Option 6: A = 410 Ω
Zero balance0±0.1
Applicationplatform scale
IP RatingIP67
Description

IPW15A  7.5kg to 200kg Single Point Load Cell 



Special features
- Stainless steel
- Maximum capacities:7.5 kg...200 kg
- Constricted minimum scale interval (v min ) for multirange applications
- OIML R60 test report
- Off‐center load compensated (OIML R 76)
- Degree of protection IP67 (per EN60529)
- 6‐wire configuration
- Meets EMC guidelines (EN 45501)
Optional:
- Explosion‐proof versions
- Various cable lengths
- Aligned output, suitable for
parallel connection

Type

IPW15B

Accuracy class1)

C3MR

Number of load cell intervals (nLC)

3000

Maximum capacity (Emax)2))

kg

7.5

15

20

30

50

75

100

150

200

 

Minimum LC verification interval (vmin)

Accuracy class C3

g

0.5

1

2

2

5

5

10

10

20

 

Temperature effect on

zero balance (TK0)

Accuracy class C3

 

% v.

Cn /

10 K

 

±0.0093

±0.0093

±0.0140

±0.0093

±0.0140

±0.0093

±0.0140

±0.0093

±0.0140


Max. platform size

mm

500 x 400

Sensitivity (Cn)

mV/V

2.0±0.2 (Option 6: A = 2mV/V±0.1%)

Zero balance

0±0.1

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40  [+68 ... +104]

−10 ... +20  [+14 ... +68]

% v.

Cn /

10 K

 

±0.0175

±0.0117

Hysteresis error (dhy)3)

% of Cn

±0.0166

Non-linearity (dlin)3)

±0.0166

Minimum dead load output return (DR)

±0.0166

Off center load error4)

±0.0233

Input resistance (RLC)

Ω

380±15

Output resistance (R0)

359±5(Option 6: 359±0.2 Ω)

Reference excitation voltage (Uref)

V

5

Nominal range of excitation voltage (BU)

1-12

Max. excitation voltage

15

Insulation resistance (Ris) at 100 VDC

> 1

Nominal temp. range (BT)

°C

[°F]

−10 ... +40

Service temp. range  (Btu)

−10 ... +50

Storage temp. range (Btl)

−25 ... +70

Safe load limit (EL ), at max.

100mm eccentricity

% of

Emax

150

Lateral load limit (Elq), static

% of

Emax

300

Breaking load (Ed)

300

Weight (G), approx.

kg

1

Protection class according to

EN 60 529 (IEC 529)

 

IP67

Material: Measuring element

Coating

Cable sheath

 

Steel 1.4545

Silicone rubber

PVC