IPW2D 7.2kg to 72kg Single Point Load Cell for dynamic weighing
IPW2D 7.2kg to 72kg Single Point Load Cell for dynamic weighing
Model
IPW2D

Item specifics

Type
Single Point Load Cell
Material
Aluminum load cell
Capacity
7.2kg to 72kg
Sensitivity
2.0±0.2
Accuracy
C3, C3MR
Input impedance
300 ... 500
Output impedance
300 ... 500
Zero balance
0±0.1
Application
static weighing
IP Rating
IP67

Product review

Description

IPW2D 7.2kg to 72kg Single Point Load Cell 
for dynamic weighing


Special features

− Accuracy class C3 with OIML-R60 test report

− Max. capacities: 7.2 kg ... 72 kg

− Off center load compensated(OIML R76)

− Degree of protection IP67(according to EN 60 529)

− Shielded connection cable

− optimized for dynamic weighing applications

Optional:

− Connection cable in six wire circuit

− Different cable lengths

− Aligned output, suitable for

Aligned output, suitable for connectionin parallel


Type

IPW2D

Accuracy class1)

C3; C3MR

Number of load cell intervals (nLC)

3000

Maximum capacity (Emax)2))

kg

7.2

12

18

36

72

 

Minimum LC verification interval (vmin)

Accuracy class C3

g

1

2

5

10

20

Temperature effect on

zero balance (TK0)

Accuracy class C3

 

% v.

Cn /

10 K

 

±0.0194

±0.0233

±0.0389

±0.0389

±0.0389

Minimum LC verification interval (vmin)

Accuracy class C3MR

g

0.5

1

2

5

10

Temperature effect on

zero balance (TK0)

Accuracy class C3MR

% v.

Cn /

10 K

 

±0.0097

±0.0116

±0.0155

±0.00194

±0.0194

Max. platform size

mm

380 x 380

Sensitivity (Cn)

mV/V

2.0±0.2

Zero balance

0±0.1

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40  [+68 ... +104]

−10 ... +20  [+14 ... +68]

% v.

Cn /

10 K

 

±0.0175

±0.0117

Hysteresis error (dhy)3)

% of Cn

±0.0166

Non-linearity (dlin)3)

±0.0166

Minimum dead load output return (DR)

±0.0166

Off center load error4)

±0.0233

Input resistance (RLC)

Ω

300 ... 500

Output resistance (R0)

300 ... 500

Reference excitation voltage (Uref)

V

5

Nominal range of excitation voltage (BU)

1 ... 12

Insulation resistance (Ris) at 100 VDC

> 2

Nominal temp. range (BT)

°C

[°F]

−10 ... +40 [+14 ... +104]

Service temp. range  (Btu)

−10 ... +50 [+14 ... +122]

Storage temp. range (Btl)

−25 ... +70 [−13 ... +158]

Safe load limit (EL ), at max.

100mm eccentricity

% of

Emax

150

160

Lateral load limit (Elq), static

% of

Emax

300

Breaking load (Ed)

300

Weight (G), approx.

kg

0.25

Protection class according to

EN 60 529 (IEC 529)

 

IP67

Material: Measuring element

Coating

Cable sheath

 

Aluminum

Silicone rubber

PVC