Various Cable Lengths Stainless Steel Load Cell Off ‐ Center Load Compensated

Group Single Point Load Cell
Min. Order 1 piece
Terms of Payment all
Update Time 2018-08-16
Item specifics
patternsingle point load cell
capacity7.5kg to 200kg
output2mv/v
materialStainless steel
applicationplatform scale
interchangeable brandHBM
IP protection standardIP67
accuracyC3
Non-linearity0.0166
size150*25*40
  • Description
  • Product review
IPW15A 7.5kg to 200kg Single Point Load Cell
Special features

-  Stainless steel
-  Maximum capacities:7.5 kg...200 kg
-  Constricted minimum scale interval (v min ) for multirange applications
-  OIML R60 test report
-  Off‐center load compensated (OIML R 76)
-  Degree of protection IP67 (per EN60529)
-  6‐wire configuration
-  Meets EMC guidelines (EN 45501)
Optional:

-  Explosion‐proof versions
-  Various cable lengths
-  Aligned output, suitable for
   parallel connection

TypeIPW15B
Accuracy class1)C3MR
Number of load cell intervals (nLC)3000
Maximum capacity (Emax)2))kg7.51520305075100150200 

Minimum LC verification interval (vmin)

Accuracy class C3

g0.512255101020 

Temperature effect on

zero balance (TK0)

Accuracy class C3


% v.

Cn /

10 K


±0.0093±0.0093±0.0140±0.0093±0.0140±0.0093±0.0140±0.0093±0.0140 
Max. platform sizemm500 x 400
Sensitivity (Cn)mV/V2.0±0.2 (Option 6: A = 2mV/V±0.1%)
Zero balance0±0.1

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40℃ [+68 ... +104℉]

−10 ... +20℃ [+14 ... +68℉]

% v.

Cn /

10 K


±0.0175

±0.0117

Hysteresis error (dhy)3)% of Cn±0.0166
Non-linearity (dlin)3)±0.0166
Minimum dead load output return (DR)±0.0166
Off center load error4)±0.0233
Input resistance (RLC)Ω380±15
Output resistance (R0)359±5(Option 6: 359±0.2 Ω)
Reference excitation voltage (Uref)V5
Nominal range of excitation voltage (BU)1-12
Max. excitation voltage15
Insulation resistance (Ris) at 100 VDC> 1
Nominal temp. range (BT)

°C

[°F]

−10 ... +40
Service temp. range (Btu)−10 ... +50
Storage temp. range (Btl)−25 ... +70

Safe load limit (EL ), at max.

100mm eccentricity

% of

Emax

150
Lateral load limit (Elq), static

% of

Emax

300
Breaking load (Ed)300
Weight (G), approx.kg1

Protection class according to

EN 60 529 (IEC 529)

 IP67

Material: Measuring element

Coating

Cable sheath

 

Steel 1.4545

Silicone rubber

PVC




    Loading...